DeepUnity

Model validation

How the transformer's unity compares with Abaqus on cases it never saw, next to the BiLSTM.

Both tools use the transformer by default. It predicts the section forces and moments of every element (axial force, two bending moments, torsion), and unity follows from the ASME B31.8 equations described in Results and code checks. The ISOPE 2026 BiLSTM, which predicts unity directly, stays selectable in both tools.

All comparisons below are against Abaqus. The error is on each jumper’s governing (largest) unity: predicted minus Abaqus, so a positive bias means the model reads conservative.

The unity equations reproduce Abaqus exactly

Given the Abaqus forces and moments, the site’s B31.8 code reproduces the unity of all 9,394 held-out cases to within one part in a million. Every difference below is the network’s.

Held-out cases from the training campaign

Cases from the same generator as the training data, never used in training. The BiLSTM was trained on part of this campaign, so it is compared only on the 2,160 cases neither model saw.

ModelCasesRMSEBias95 % of errors withinExceedances of 1.0 missed
Transformer9,3940.021+0.0110.0407 of 4,667
Transformer2,1600.022+0.0130.0433 of 1,186
BiLSTM2,1600.021+0.0050.0426 of 1,186

Every missed exceedance had an Abaqus unity between 1.000 and 1.035. The transformer places the governing element in the right part of the jumper (hub, shoulder or belly) in 97.8 % of cases, against 96.2 % for the BiLSTM.

An independent Abaqus campaign

845 Abaqus runs made after training: 169 jumpers, each at five operating states (normal operation, turndown, partial operation, a minor swing and cold high-pressure).

ModelRunsRMSEBias95 % of errors withinExceedances of 1.0 missed
Transformer8450.046+0.0290.0960 of 335
BiLSTM8450.042+0.0230.0920 of 335

Both models read about 0.03 high on this campaign, on the safe side. The likely cause is how its operating states were sampled; it is under investigation.

What this means for you

  • Expect the governing unity within about ±0.04 of Abaqus inside the training ranges, usually a little high.
  • Near 1.0, treat results between about 0.95 and 1.05 as needing a finite-element check.
  • Outside the training ranges, errors grow; the tools flag those inputs.

Last updated October 2026